VACUREMA® PRIME | System throughput | Reference IV-performance* | Total energy consumption** (0.35 kWh/kg) | System process duration | Flake reactor vacuum | Flake reactor performance | Extruder | Pellet form | Final pellet quality | Space needed | Height / KT height |
---|---|---|---|---|---|---|---|---|---|---|---|
Model | Maximum [kg/h] | [dl/g @ kg/h] | [kWh/h] | Total [h] | [mbar] Advantages | Residual moisture | L/D drive-rating [kW] | Granumetry | AA level VOCs | [m²] | [m / m] |
VACUREMA® PRIME 1310 T | -600 | 0,82 @ 500 | 175 | 3h | < 5 redundant filter | Residual moisture < 50ppm several national and international approvals |
~ 27 75kW |
spherical or cylindrical inline crystallised | < 2 - 4 ppm < 1 ppm with OPTIONAL Pellet Flusher brand owner status depending on setup | 285 | 6,0 / 9,0 |
VACUREMA® PRIME 1512 T | -900/td> | 0,82 @ 700 | 245 | 3h | < 5 redundant filter | ~ 27 110kW |
spherical or cylindrical inline crystallised | 295 | 6,0 / 9,5 | ||
VACUREMA® PRIME 1714 T | -1000/td> | 0,82 @ 850 | 298 | 3h | < 5 redundant filter | ~ 27 160kW |
spherical or cylindrical inline crystallised | 320 | 6,0 / 10 | ||
VACUREMA® PRIME 1716 T | -1500/td> | 0,82 @ 1250 | 438 | 3h | < 5 redundant filter | ~ 27 200kW |
spherical or cylindrical inline crystallised | 330 | 6,0 / 10,5 | ||
VACUREMA® PRIME 2018 T | -2000/td> | 0,82 @ 1500 | 525 | 3h | < 5 redundant filter | ~ 27 315kW |
spherical or cylindrical inline crystallised | 360 | 6,0 / 11 | ||
VACUREMA® PRIME 2318 T | -2050/td> | 0,82 @ 2000 | 700 | 3h | < 5 redundant filter | ~ 27 315kW |
spherical or cylindrical inline crystallised | 400 | 6,0 / 11 | ||
VACUREMA® PRIME 2021 T | -2350/td> | 0,82 @ 1850 | 648 | 3h | < 5 redundant filter | ~ 27 315kW |
spherical or cylindrical inline crystallised | 385 | 6,0 / 11,5 | ||
VACUREMA® PRIME 2321 T | -2600/td> | 0,82 @ 2300 | 805 | 3h | < 5 redundant filter | ~ 27 400kW |
spherical or cylindrical inline crystallised | 410 | 6,0 / 12,5 | ||
VACUREMA® PRIME 2621 T | -3000/td> | 0,82 @ 2750 | 963 | 3h | < 5 redundant filter | ~ 27 400kW |
spherical or cylindrical inline crystallised | 475 | 6,0 / 12 | ||
VACUREMA® PRIME 2625 T | -3600/td> | 0,82 @ 3000 | 1050 | 3h | < 5 redundant filter | ~ 27 500kW |
spherical or cylindrical inline crystallised | 495 | 6,0 / 12 | ||
VACUREMA® PRIME 2628 T | -4700/td> | 0,82 @ 3500 | 1225 | 3h | < 5 redundant filter | ~ 27 560kW |
spherical or cylindrical inline crystallised | 530 | 6,0 / 11,5 |
* At an input flake IV of 0.76 dl/g
**including expected power consumption of necessary water chillers at the customer´s plant